Moisture Uptake Derating Factor for Paper Versus PP

A moisture uptake derating factor reduces an allowable load by the mass and stiffness change a material shows after conditioning. ... Ask Mingskye for a sample.

A moisture uptake derating factor reduces an allowable load by the mass and stiffness change a material shows after conditioning. Measure the property before and after a defined humidity exposure, divide the conditioned value by the dry value, and apply that fraction to the load limit. A worked example with illustrative readings shows a paper core and a PP flange on the same scale. State the exposure condition with the factor, and keep it separate from the temperature factor.

This page covers moisture uptake derating factor in six sections: Sensitivity to regrind source; Computing the load margin as a ratio; Sensitivity to cleaning cost; Forming the humidity derating factor; Reading the creep slope rather than one point; Subtracting hub and cable expansion. Each section answers one practical question and can be read on its own.

moisture uptake derating factor - PP hollow sheet cable reel sizing reference from Mingskye

Key facts

  • A change of regrind source can move the retention curve without any change in blend fraction.
  • A load margin is the allowable limit divided by the calculated demand, expressed as a dimensionless ratio.
  • Cleaning cost is the largest variable cost a reusable pool adds.
  • A humidity derating factor is the conditioned value divided by the reference value.
  • A single deformation reading cannot tell you whether creep is still accelerating.

Sensitivity to regrind source

A change of regrind source can move the retention curve without any change in blend fraction.

Re-measure retention and melt flow slope when the source, the washing process or the particle size changes. Compare the new curve with the one that set the current limit.

A limit derived from one source should not be carried over silently to another. Re-approval is a measurement task, not an administrative update.

  • Re-measure after any source change
  • Compare with the current curve
  • Re-approve the limit

Computing the load margin as a ratio

A load margin is the allowable limit divided by the calculated demand, expressed as a dimensionless ratio.

Divide the allowable deflection by the computed deflection. A result above one means reserve remains; a result near one means any change in tension or thickness consumes the reserve. An illustrative doubling of pressure halves the margin.

A ratio is more portable than an absolute difference because it can be compared across reel sizes and load cases on one scale.

  • Divide allowable by demand
  • Treat a value near one as a warning
  • Use ratios across different sizes

For terminology and test-method context see ISO standards catalogue. The guidance on this page is practical handling guidance, not a test report or a certificate.

Sensitivity to cleaning cost

Cleaning cost is the largest variable cost a reusable pool adds.

Recompute the net saving per trip at a low, a mid and a high illustrative cleaning cost, holding all other inputs fixed. The break-even count moves with each step.

Break cleaning into labour, water, energy and reject handling. A single bundled figure hides which element is driving the sensitivity.

  • Vary cleaning cost in three steps
  • Hold all other inputs fixed
  • Split the cost into its elements
Environment question Short answer Derating factor In this guide
What should be checked about sensitivity to regrind source? A change of regrind source can move the retention curve without any change in blend fraction. Re-measure retention and melt flow slope when the source, the washing process or the particle … Section 1
What should be checked about computing the load margin as a … A load margin is the allowable limit divided by the calculated demand, expressed as a dimensionless … Divide the allowable deflection by the computed deflection. A result above one means reserve remains … Section 2
What should be checked about sensitivity to cleaning cost? Cleaning cost is the largest variable cost a reusable pool adds. Recompute the net saving per trip at a low, a mid and a high illustrative … Section 3
What should be checked about forming the humidity derating factor? A humidity derating factor is the conditioned value divided by the reference value. Divide the post-exposure measurement by the dry measurement to obtain a fraction below one, then … Section 4

Forming the humidity derating factor

A humidity derating factor is the conditioned value divided by the reference value.

Divide the post-exposure measurement by the dry measurement to obtain a fraction below one, then multiply the reference load limit by it. An illustrative paper core and a PP flange produce different fractions on the same rig.

Keep this factor separate from temperature and cycle count. Combining them before each is understood hides which condition is driving the reduction.

  • Divide conditioned by reference
  • Apply to the load limit
  • Keep factors separate

Reading the creep slope rather than one point

A single deformation reading cannot tell you whether creep is still accelerating.

Compare the slope over the first and last parts of the exposure. A flattening slope suggests the change is slowing, while a sustained slope suggests a continuing process.

Use the slope to set a maximum dwell time before winding or despatch. An endpoint reading gives no information about how long the part can safely wait.

  • Compare early and late slopes
  • Watch for a sustained slope
  • Set a maximum dwell time

Subtracting hub and cable expansion

The mismatch length is the difference between the two computed expansions.

Subtract the cable expansion from the hub expansion and keep the sign. A positive mismatch means the hub grows more than the cable at that temperature difference.

Use the mismatch as a length, not as a percentage. It feeds directly into the tension window bound on the next step.

  • Keep the sign of the difference
  • Express as a length
  • Carry into the tension window

Frequently asked questions

Which two measurements form the factor?

A change of regrind source can move the retention curve without any change in blend fraction. Re-measure retention and melt flow slope when the source, the washing process or the particle size changes. Compare the new curve with …

How is the factor applied?

A load margin is the allowable limit divided by the calculated demand, expressed as a dimensionless ratio. Divide the allowable deflection by the computed deflection. A result above one means reserve remains; a result near one means any change …

Why keep it separate from temperature?

A humidity derating factor is the conditioned value divided by the reference value. Divide the post-exposure measurement by the dry measurement to obtain a fraction below one, then multiply the reference load limit by it …

What must be stated with it?

The mismatch length is the difference between the two computed expansions. Subtract the cable expansion from the hub expansion and keep the sign. A positive mismatch means the hub grows more than the …

Sources and further reading

  • ISO standards catalogue: packaging, transport and plastics test methods — www.iso.org
  • ASTM International: standard test methods for plastics and packaging — www.astm.org
  • PlasticsEurope: polypropylene material properties and recycling information — plasticseurope.org
  • BIPM SI Brochure: units, prefixes and rules for expressing measured quantities — www.bipm.org

References checked by publisher and title on 2026-11-17. Standards and regulations are cited by name only; no performance values are attributed to them. Every figure and every worked example in the text uses illustrative input values, not measured product data; substitute your own measured inputs and verify them against your supplier’s current data sheet and a trial before use. Confirm applicability and current versions for your own operation before relying on any of them.

Related Mingskye cable reels

For a quotation, a sample reel or help substituting your own cable diameter, winding length, stack height and return route into these calculations on site, contact service@mingplastics.com or WhatsApp +86 189 3887 1524. Include the cable type, the destination, the expected cycles per year and the figures your finance and sustainability teams need to defend so the recommended specification can be confirmed before you order.

Final takeaway

For moisture uptake derating factor, Apply one derating factor per environmental variable and show the combined factor in the final line. The mismatch length is the difference between the two computed expansions.