{"id":6983,"date":"2026-10-28T06:55:33","date_gmt":"2026-10-28T06:55:33","guid":{"rendered":"https:\/\/www.mingplastics.com\/pp-honeycomb-protection-board-atrium-void-works.html"},"modified":"2026-10-28T06:55:33","modified_gmt":"2026-10-28T06:55:33","slug":"pp-honeycomb-protection-board-atrium-void-works","status":"publish","type":"post","link":"https:\/\/www.mingplastics.com\/fr\/pp-honeycomb-protection-board-atrium-void-works.html","title":{"rendered":"PP Honeycomb Protection Board in Atria and Over Void Works: Protection at Height"},"content":{"rendered":"<div style=\"text-align:center;margin-bottom:30px\"><a href=\"https:\/\/www.mingplastics.com\/fr\/produit\/custom-reusable-pp-honeycomb-protection-board-with-felt-surface-for-floor-wall-a\/\"><img decoding=\"async\" src=\"https:\/\/www.mingplastics.com\/wp-content\/uploads\/2026\/08\/PP-Honeycomb-Felt-Board-064.jpg\" alt=\"PP honeycomb protection board application\" style=\"max-width:100%;height:auto;border-radius:8px\"><\/a><\/div>\n<p>Atrium and void works combine height, public visibility and expensive floors below, so protection has to manage dropped objects as well as traffic. This article looks at protecting atrium floors and working over voids. The focus is dropped-object protection, public visibility and working at height safely.<\/p>\n<h2>Over a void, dropped objects are the main risk<\/h2>\n<p>In an atrium, the floor below is at risk from anything dropped from above, and the consequence is damage plus a safety incident. Protection has to resist impact as well as traffic.<\/p>\n<p>A rigid PP honeycomb protection board absorbs and spreads impact while giving a working surface, and because it is light it can be placed at height without heavy handling.<\/p>\n<p>Confirm the fire performance required, because atrium spaces often have specific material standards.<\/p>\n<h2>Thickness choices from 2 mm to 12 mm<\/h2>\n<p>Atrium works involve impact and equipment, so the middle to upper part of the 2 mm to 12 mm range is typical.<\/p>\n<p>For pedestrian protection below, a mid thickness may be sufficient. Where tools and components are handled above, thicker boards give better impact resistance.<\/p>\n<div style=\"overflow-x:auto\">\n<table style=\"border-collapse:collapse;width:100%\">\n<thead>\n<tr>\n<th scope=\"col\" style=\"border:1px solid #ccd9dc;padding:10px;text-align:left\">Board group<\/th>\n<th scope=\"col\" style=\"border:1px solid #ccd9dc;padding:10px;text-align:left\">Typical thickness<\/th>\n<th scope=\"col\" style=\"border:1px solid #ccd9dc;padding:10px;text-align:left\">Where it earns its place<\/th>\n<th scope=\"col\" style=\"border:1px solid #ccd9dc;padding:10px;text-align:left\">Watch-outs<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">Light-duty panel<\/td>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">2-3 mm<\/td>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">Pedestrian protection below works<\/td>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">Limited impact resistance<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">General atrium panel<\/td>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">4-6 mm<\/td>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">Atrium floors under works and light impact<\/td>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">Secure against movement; fire performance<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">Heavy-duty panel<\/td>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">8-10 mm<\/td>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">Tool and component handling above<\/td>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">Confirm fire and safety requirements<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">Maximum protection<\/td>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">12 mm<\/td>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">Heaviest works over occupied atrium floors<\/td>\n<td style=\"border:1px solid #ccd9dc;padding:10px\">Use barriers and catch platforms as required<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Public visibility and working at height<\/h2>\n<p>Keep the protected area tidy and edges finished, because an atrium is usually visible from every floor and poor housekeeping is highly visible.<\/p>\n<p>Secure panels against movement and wind effects in tall spaces, and inspect after any work at height above them.<\/p>\n<p>Coordinate with the building&#8217;s safety rules for work over voids, including any requirement for barriers or catch platforms in addition to protection.<\/p>\n<h2>How honeycomb board compares with ply, scaffold board and sheeting<\/h2>\n<p>Scaffold boards and ply are traditional but heavy to place at height and absorb water in open atria.<\/p>\n<p>Sheeting catches debris but is a trip hazard and offers no impact resistance or working surface.<\/p>\n<p>A PP honeycomb board is light, gives a working surface and resists impact, which suits protection in a tall public space.<\/p>\n<h2>A practical trial plan for atrium works<\/h2>\n<p>Protect one zone below the works and leave a comparable zone on the current method. Inspect after each work-at-height session.<\/p>\n<p>Run a dropped-object test from the working height onto a sample panel under controlled conditions, then inspect both sides.<\/p>\n<p>Record any movement of panels and any impact damage, because in an atrium both signal the need to change the method.<\/p>\n<h2>What to include in a protection board enquiry<\/h2>\n<p>State the floor finish, the works height, what is being handled above and the fire performance required. Ask for the recommended thickness for impact resistance.<\/p>\n<p>Ask for guidance on securing panels in tall spaces and about custom sizes for atrium dimensions.<\/p>\n<p>For a quotation or sample panel, contact <a href=\"mailto:service@mingplastics.com\">service@mingplastics.com<\/a> or WhatsApp <a href=\"https:\/\/wa.me\/8618938871524\">+86 189 3887 1524<\/a>. Include the surface type, floor area, trades on site and expected duration so the recommended thickness, facing and fire performance can be confirmed before you order.<\/p>\n<h3>Final takeaway<\/h3>\n<p>In atria, specify for impact as well as traffic, secure panels against movement, confirm fire performance and follow the building&#8217;s rules for work over voids.<\/p>","protected":false},"excerpt":{"rendered":"<p>Atrium works risk dropped objects onto expensive floors. This guide covers thickness from 2 mm to 12 mm, impact resistance and an atrium trial plan.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-6983","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/www.mingplastics.com\/fr\/wp-json\/wp\/v2\/posts\/6983","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mingplastics.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mingplastics.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mingplastics.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mingplastics.com\/fr\/wp-json\/wp\/v2\/comments?post=6983"}],"version-history":[{"count":0,"href":"https:\/\/www.mingplastics.com\/fr\/wp-json\/wp\/v2\/posts\/6983\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.mingplastics.com\/fr\/wp-json\/wp\/v2\/media?parent=6983"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mingplastics.com\/fr\/wp-json\/wp\/v2\/categories?post=6983"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mingplastics.com\/fr\/wp-json\/wp\/v2\/tags?post=6983"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}